Name:

Overhead insulated cable

No.:
Affiliate classification:
没有此类产品
I want to make an inquiry
Detail

It is mainly used for overhead fixed laying, line drawing and other places.

 

Overhead insulated cables can reduce laying gap, save line corridors, reduce power supply accidents and ensure personal safety.

 

Overhead insulated cables with the rated voltage of 1 kV and below 

 

 

purpose

This product is applicable to the overhead cables with copper core, aluminum core or aluminum alloy core weatherable polyvinyl chloride (PVC), polyethylene (PE) and crosslinked polyethylene (XLPE) insulations for the overhead power lines with the AC rated voltage U0/U of 0.6/1kv and below.


Applicable conditions

1. The rated voltage U0/U is 0.6/1 kV.

2. The long-term allowable operating temperature of the cable conductor: The temperature of PVC and PE insulations shall not exceed 70°C; the temperature of XLPE insulation shall not exceed 90°C;

3. The cable laying temperature shall not be lower than -20°C.

4. The allowable bending radius of cable: For the cable with the outer diameter lower than 25 mm, the radius shall not be lower than 4D. For the cable with the outer diameter of 25 mm and above, the radius shall not be lower than 6D.

 

Type and name

Model

Name

Main uses

JKV-0.6/1kV

Copper-core PVC insulated overhead cable with the rated voltage of 0.6/1 kV 

Overhead fixed laying, leading line, etc.

JKLV-0.6/1kV

Overhead fixed laying, leading service wire, etc. 

JKLHV-0.6/1kV

Aluminum-core PVC insulated overhead cable with the rated voltage of 0.6/1 kV 

JKY-0.6/1kV

Aluminum-alloy-core PVC insulated overhead cable with the rated voltage of 0.6/1 kV 

JKLY-0.6/1kV

Copper-core PE insulated overhead cable with the rated voltage of 0.6/1 kV 

JKLHY-0.6/1kV

Aluminum-core PE insulated overhead cable with the rated voltage of 0.6/1 kV 

JKYJ-0.6/1kV

Aluminum-core PE insulated overhead cable with the rated voltage of 0.6/1 kV 

JKLYJ-0.6/1kV

Copper-core XLPE insulated overhead cable with the rated voltage of 0.6/1 kV 

JKLHYJ-0.6/1kV

Aluminum-core XLPE insulated overhead cable with the rated voltage of 0.6/1 kV 

 

Delivery requirements
1. The goods are delivered at any length according to the agreement of both parties.
2. Cables shall be neatly wound on the delivery tray, their ends shall be sealed well, and the length stretching out of the cable tray shall meet the test requirements. Only cables of the same type and specification are allowed to be wound on a delivery tray.
3
3. In case of no agreement between both parties, the provisions of GB/T 12527-2 shall be implemented

 

10 KV XLPE insulated overhead cable 

 

 

purpose

This product is applicable to overhead power lines with the AC rated voltage U(Um) of 10 (12) kV.
Applicable conditions
1. The maximum long-term allowable operating temperature of the cable conductor is 90°C.
2. The laying temperature is not less than -20 C.
3. The maximum temperature of conductor should not be greater than 250 C when short circuit (the longest duration does not exceed 5 seconds).
Model specification

Model

Name

Main uses

JKYJ

Copper-core XLPE insulated overhead cable 

Overhead fixed laying, and flexible copper-core products used for downlead of transformer. 

During cable erection, a certain distance shall be reserved between the cable and tree; frequent contact between the cable and tree is allowable during cable operation 

JKTRYJ

Flexible copper-core XLPE insulated overhead cable

JKLYJ

Aluminum-core XLPE insulated overhead cable 

JKLHYJ

Aluminum-alloy-core XLPE insulated overhead cable 

JKY

Copper-core PE insulated overhead cable 

JKTRY

Copper-core PE insulated overhead cable 

JKLY

Aluminum-core PE insulated overhead cable 

JKLHY

Aluminum-alloy-core PE insulated overhead cable 

JKLYJ/B

Aluminum-core natural-colour XLPE insulated overhead cable

Overhead fixed laying

During cable erection, a certain distance shall be reserved between the cable and tree; frequent contact between the cable and tree is allowable during cable operation 

JKLHYJ/B

Aluminum-alloy-core natural-colour XLPE insulated overhead cable 

JKLYJ/Q

Aluminum-core lightweight XLPE insulated overhead cable 

Overhead fixed laying

During cable erection, a certain distance shall be reserved between the cable and tree; short contact between the cable and tree is allowable during cable operation

JKLHYJ/Q

Aluminum-alloy-core lightweight XLPE insulated overhead cable 

JKLY/Q

luminum-core lightweight PE insulated overhead cable 

JKLHY/Q

Aluminum-alloy-core lightweight PE insulated overhead cable

 

Cargo requirements

1, according to the agreement between the two sides, delivery at any length.

2. The cables should be neatly wound on the delivery tray, and the ends should be sealed well. The length of the exposed cable tray should meet the test requirements. Only the same type of cable can be wound on one delivery tray.

3, when there is no agreement between the two parties, the provisions of the GB/T14049-2008 standard shall be implemented.

Corresponding parameter set not found, please add it in property template of background